Short answer

An EV PDU and a CDU can both sit within the vehicle high-voltage architecture, but they do not define the same assembly scope.

An EV PDU primarily distributes and protects high-voltage DC power between the traction battery and vehicle loads. A proposed CDU integrated system can combine onboard charging, high-voltage-to-low-voltage conversion and high-voltage distribution functions in one project-specific assembly.

The name alone does not define the product. Confirm the electrical boundary, included functions, control ownership, packaging, cooling and verification scope for the vehicle program.

  • An EV PDU architecture may fit when distribution and protection are needed while OBC and DC/DC remain separate modules or outside the supplier scope.
  • Review a CDU architecture when the project is considering an integrated assembly that may combine OBC, DC/DC and high-voltage distribution functions.
  • Neither architecture is automatically better; the decision depends on platform functions, space, thermal design, interfaces, service strategy and responsibility split.

Side-by-side comparison

Use this as an architecture discussion aid. The functions and responsibilities for a supplied assembly must be confirmed against its agreed project scope.

These are architecture references, not universal product specifications. Exact functions, ratings, interfaces and deliverables remain project-specific.

Primary role

EV PDU
High-voltage distribution, switching and protection within the defined assembly scope.
CDU integrated system
Project-specific integration of charging, conversion and high-voltage distribution functions.

Power conversion

EV PDU
Does not inherently perform OBC or HV-to-LV DC/DC conversion.
CDU integrated system
May include OBC and DC/DC conversion when confirmed in the agreed scope.

Interfaces

EV PDU
May connect the battery, inverter/e-axle, OBC path, DC/DC path and auxiliary HV loads, as applicable.
CDU integrated system
May involve the charging inlet, HV battery, LV system, HV branches, cooling and vehicle-control interfaces, as applicable.

Packaging

EV PDU
A separate distribution assembly with external power-electronics modules where the architecture uses them.
CDU integrated system
A shared or coordinated package for the functions included in the project scope.

Cooling

EV PDU
Review conductor, connection, switching/protection losses and installation conditions.
CDU integrated system
Also review conversion losses and the combined thermal architecture when those functions are included.

Control boundary

EV PDU
Define switching, feedback and diagnostic responsibilities with vehicle controllers.
CDU integrated system
Align charging, conversion, distribution and vehicle-control responsibilities across included functions.

Service and validation

EV PDU
Set service boundaries and verification criteria for the specified PDU configuration.
CDU integrated system
Set service boundaries and criteria for the included integrated electrical, thermal, interface and assembly scope.

What an EV PDU does

An EV PDU routes high-voltage DC power from the traction-battery side to defined vehicle loads and branches. Depending on the agreed architecture, its scope may include distribution conductors, contactors, fuses, pre-charge elements, sensing interfaces and control or status connections.

The OBC and DC/DC converter can connect through the PDU while remaining separate modules. A listed branch does not mean charging or voltage-conversion electronics are built into the PDU.

What a CDU integrated system does

A proposed TRHT CDU configuration can integrate OBC, DC/DC and high-voltage power distribution functions. The included functions and assembly boundary are confirmed against the vehicle architecture and agreed project scope.

In general, an onboard charger converts grid-side AC power into controlled DC power for charging the traction battery, while an HV-to-LV DC/DC stage supplies the vehicle low-voltage system. The high-voltage distribution section routes the branches assigned to it. The CDU name alone does not establish that every function is included; confirm the block diagram, interfaces, ratings and responsibilities for the specific configuration.

Architecture decisions to review

  • Included electrical functions: OBC, HV-to-LV conversion, distribution branches, switching/protection, pre-charge, sensing and control interfaces, as applicable.
  • Packaging and harness: envelope, mounts, connector locations, internal/external harness routes, sealing and service access.
  • Thermal design: ambient conditions, duty cycle, available cooling and simultaneous operating modes for the proposed configuration.
  • Control and responsibility: ownership of charging commands, conversion, contactor control, fault response, diagnostics and state feedback.
  • Verification and change control: agree applicable configuration, conditions, acceptance criteria and available records; do not transfer evidence automatically between configurations.

When each architecture may fit

A discrete EV PDU may fit when OBC and DC/DC are already separate modules, a dedicated distribution assembly is required, or module sourcing and service boundaries should remain distinct. A CDU may be considered when coordinated integration supports the vehicle packaging and harness plan and the project can define combined cooling, control and validation responsibilities. These are decision inputs, not universal recommendations; final selection requires vehicle-level review.

Information to include in a CDU or EV PDU RFQ

Share the information available for the vehicle program. Preliminary or unknown items can be marked TBD; final functions, ratings, interfaces, verification scope and commercial terms are confirmed during project review.

  • Vehicle high-voltage/low-voltage architecture or a sanitized single-line diagram.
  • Minimum, nominal and maximum battery voltage, plus branch continuous/peak current, duration and simultaneous operating conditions.
  • OBC charging function and DC/DC output requirements, where applicable.
  • Switching, protection, pre-charge, sensing, control and communication responsibilities.
  • Installation envelope, connectors, mounting, cable exits, cooling and environmental requirements.
  • Project stage, prototype quantity, production context and requested verification evidence.

Technical references

  1. Texas Instruments: HEV/EV OBC & DC/DC converter resources

    General background on OBC and DC/DC roles; not evidence of TRHT product ratings, certification or completed validation.

  2. Infineon: On-board charging (OBC)

    General OBC context only; not a TRHT product specification or validation record.

References explain general concepts, not verified TRHT ratings or certification. Required product evidence remains configuration-specific.

Frequently asked questions

Is every CDU a three-in-one OBC, DC/DC and PDU?+

No. A proposed CDU configuration can integrate these functions, but the included functions and assembly boundary must be confirmed for the project.

Does an EV PDU include an onboard charger?+

Not inherently. An EV PDU can distribute power to or from an OBC branch while the charger remains a separate module. Any integrated OBC electronics should be explicitly included in the agreed product scope.

Is a CDU always smaller than separate modules?+

Not necessarily. Integration may coordinate enclosure and interfaces, but final size depends on the functions, cooling, insulation, service access and packaging constraints.

Does integration reduce verification work?+

It changes the verification boundary. Agree the configuration, conditions and acceptance criteria for the included functions and interfaces.

What is a useful first document for comparison?+

A vehicle block diagram or sanitized single-line diagram helps identify power paths, conversion functions, branches and control boundaries.

Need a customized HV PDU for your program?

Share voltage, current, topology, and project stage. TRHT engineering supports English RFQs for Europe, North America, and Asia-Pacific.